This soft copy for use by IBM employees only.
containing an IBM 8260 module, the value enable(1) causes the module to be
::= { ocPowerSlotEntry 3 }
ocPowerSlotOperStatus |
|
SYNTAX INTEGER { |
|
enabled(1), | |
disabled(2), | |
} |
|
ACCESS |
|
STATUS mandatory |
|
DESCRIPTION |
|
″The current operational slot power status. This object will have the value enabled(1), if the slot contains an IBM 8260 module and is actually
IBM 8260 module and is actually
the value
For the slot containing the IBM 8260 agent, ocPowerSlotAdminStatus cannot be set to the value disable(2). However, in the event of an environmental change such as a power supply failure, the slot containing the IBM 8260 agent may be automatically
and this object will then have the value
::= { ocPowerSlotEntry 4 }
--IBM 8260 Inventory Group
--This group reflects inventory information about
--components in the IBM 8260 hub.
--Hub chassis information
ocInvHubType
SYNTAX DisplayString (SIZE(1..32)) ACCESS
STATUS mandatory
DESCRIPTION
″The hub type (i.e. model number) of the hub. An instance
for which information is not valid will return ′ invalid EEPROM!′ . ″
::= { ocInvHub 1 }