This soft copy for use by IBM employees only.

containing an IBM 8260 module, the value enable(1) causes the module to be power-enabled, provided sufficient power is available. The value disable(2) causes the module to be power-disabled and is not allowed for a slot containing the IBM 8260 agent, to prevent the user from losing hub manageability. The slot will not receive power untill this object is set to the the value enable(1).″

::= { ocPowerSlotEntry 3 }

ocPowerSlotOperStatus OBJECT-TYPE

 

SYNTAX INTEGER {

 

enabled(1),

-- Slot power is enabled

disabled(2),

-- Slot power is disabled

insufficient-power(3),

-- Slot power up not possible

enabled-always(4)

-- Slot power is enabled always

}

 

ACCESS read-only

 

STATUS mandatory

 

DESCRIPTION

 

The current operational slot power status. This object will have the value enabled(1), if the slot contains an IBM 8260 module and is actually power-enabled. This object will have the value disabled(2), if the slot contains an

IBM 8260 module and is actually power-disabled. In this case, the slot is ineligible for power until ocPowerSlotAdminStatus for the slot is set to enable(1). This object will have

the value insufficient-power(3), if the slot is eligible to receive power but, due to power constraints, is not power-enabled. When sufficient power becomes available, the slot will become power-enabled, and this object will then have the value enabled(1). This object will have the value enabled-always(4) for a slot containing the IBM 8260 agent.

For the slot containing the IBM 8260 agent, ocPowerSlotAdminStatus cannot be set to the value disable(2). However, in the event of an environmental change such as a power supply failure, the slot containing the IBM 8260 agent may be automatically power-disabled,

and this object will then have the value insufficient-power(3). This is based on the value of ocPowerSlotClass for the slot.″

::= { ocPowerSlotEntry 4 }

--

--IBM 8260 Inventory Group

--This group reflects inventory information about

--components in the IBM 8260 hub.

--

--

--Hub chassis information

ocInvHubType OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..32)) ACCESS read-only

STATUS mandatory

DESCRIPTION

The hub type (i.e. model number) of the hub. An instance

for which information is not valid will return ′ invalid EEPROM!′ . ″

::= { ocInvHub 1 }

270ATM Workgroup Solutions: Implementing the 8285 ATM Switch

Page 286
Image 286
IBM SG24-4817-00 manual Syntax Integer