ocPowerModeOperStatus OBJECT-TYPE SYNTAX INTEGER {

fault-tolerant(1), not-fault-tolerant(2)

}

ACCESS read-only STATUS mandatory

DESCRIPTION

The current operational status of hub power fault-tolerant mode.″

::= { ocPowerControl 2 }

ocPowerOverheatPowerDownMode OBJECT-TYPE SYNTAX INTEGER {

enable(1),

disable(2)

}

ACCESS read-only STATUS mandatory

DESCRIPTION

The current desired state of hub overheat automatic power- down mode. The value enable(1) causes slots containing IBM 8260 modules to be automatically power-disabled during a hub

overheat condition. The value disable(2) causes no action to be taken when a hub overheat condition occurs.″

::= { ocPowerControl 3 }

--

--Hub backplane power

ocPowerOutputTable OBJECT-TYPE

SYNTAX SEQUENCE OF OcPowerOutputEntry ACCESS not-accessible

STATUS mandatory

DESCRIPTION

A table that contains information about the hub power budget. This table is indexed by voltage line type, each

of which is supplied by the operational power supplies.″ ::= { ocPower 2 }

ocPowerOutputEntry OBJECT-TYPE SYNTAX OcPowerOutputEntry ACCESS not-accessible STATUS mandatory

DESCRIPTION

″A list of information about the hub power budget.″ INDEX { ocPowerOutputType }

::= { ocPowerOutputTable 1 }

OcPowerOutputEntry ::=

SEQUENCE { ocPowerOutputType

INTEGER, ocPowerOutputVoltageLevel

Gauge, ocPowerOutputWattageCapacity

Gauge, ocPowerOutputWattageConsumed

Gauge,