DESCRIPTION
″ A PVC failure trap is sent when a PVC becomes inoperational.″ ::= 4
callLoggingOverflow
DESCRIPTION
″A callLoggingOverflow trap is sent when the call logging table
is about to wrap.″ ::= 6
moduleInstalled
VARIABLES { moduleSlotIndex }
DESCRIPTION
″ An ATM module has been detected in the hub.″ ::= 7
moduleRemoved
VARIABLES { moduleSlotIndex }
DESCRIPTION
″ An ATM module is no longer detected in the hub.″ ::= 8
lesMaxClientsReached
DESCRIPTION
″The maximum number of lan emulation
clients has been connected to the given lan emulation server.″
::= 9
lesMaxClientsThresholdDown
DESCRIPTION
″The number of operational clients of the given emulated lan is now equal to lesMaxNumberOfClients - 10.
This trap is sent only if the
trap lesMaxClientsReached has been sent previously. lesIndex is the index of the lesConfTable defined above″ ::= 10
--Expansion Description
expansion OBJECT IDENTIFIER ::= { atmSw 4 }
expansionHardwareVersion
STATUS mandatory
DESCRIPTION
″The Part Number (P/N) and Engineering Change (EC) level and Plant Location for this module.″
::= { expansion 1 }
Appendix E. IBM ATM Campus Switch Private MIBs 255