This soft copy for use by IBM employees only.

DESCRIPTION

″ A PVC failure trap is sent when a PVC becomes inoperational.″ ::= 4

-- node.5 intentionnally left unused

callLoggingOverflow TRAP-TYPE ENTERPRISE node

DESCRIPTION

A callLoggingOverflow trap is sent when the call logging table

is about to wrap.″ ::= 6

moduleInstalled TRAP-TYPE ENTERPRISE node

VARIABLES { moduleSlotIndex }

DESCRIPTION

″ An ATM module has been detected in the hub.″ ::= 7

moduleRemoved TRAP-TYPE ENTERPRISE node

VARIABLES { moduleSlotIndex }

DESCRIPTION

″ An ATM module is no longer detected in the hub.″ ::= 8

lesMaxClientsReached TRAP-TYPE ENTERPRISE node VARIABLES { lesIndex }

DESCRIPTION

The maximum number of lan emulation

clients has been connected to the given lan emulation server.″

::= 9

lesMaxClientsThresholdDown TRAP-TYPE ENTERPRISE node VARIABLES { lesIndex }

DESCRIPTION

The number of operational clients of the given emulated lan is now equal to lesMaxNumberOfClients - 10.

This trap is sent only if the

trap lesMaxClientsReached has been sent previously. lesIndex is the index of the lesConfTable defined above″ ::= 10

--Expansion Description

expansion OBJECT IDENTIFIER ::= { atmSw 4 }

expansionHardwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only

STATUS mandatory

DESCRIPTION

The Part Number (P/N) and Engineering Change (EC) level and Plant Location for this module.″

::= { expansion 1 }

Appendix E. IBM ATM Campus Switch Private MIBs 255