SYNTAX INTEGER {

one(1), -- lowest two(2),

three(3),

four(4),

five(5),

six(6),

seven(7),

eight(8),

nine(9),

ten(10), -- highest never(11)

}

ACCESS read-only STATUS mandatory

DESCRIPTION

The mastership priority of this agent. Ten is the highest and one is the lowest. Never means will not

be able become master. MasterPriority is only used

when an election occurs. Mastership is not pre-emptive.″

::= { agentsEntry 5 }

ocAgentsSubSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory

DESCRIPTION

The subslot index for this agent. For agents not located

in the IBM 8260 system, this object will always return 1 for this object value.″

::= { agentsEntry 6 }

--The conc Group:

--This group is mandatory for all devices that are acting as a concentrator

--master.

--

--The conc group contains information and control relative to

--the concentrator.

--

concType OBJECT-TYPE SYNTAX INTEGER {

hub-8260-017-A(6), -- 17-slot with ring backplane

hub-8260-010-A(10) -- 10-slot with ring backplane

}

ACCESS read-only STATUS mandatory

DESCRIPTION

This object identifies the type of concentrator represented by this agent.″

::= { conc 1 }

concReset OBJECT-TYPE SYNTAX INTEGER {

noReset(1),

reset(2)

}

258ATM Workgroup Solutions: Implementing the 8285 ATM Switch

Page 274
Image 274
IBM SG24-4817-00 manual NoReset1 Reset2