Figure 41. Multi-Switch CIP Network - Logical View
The necessary parameters for our second switch are listed below in Table 33. Please note that the ACN is the same, indicating that both switches are in the same cluster and will therefore communicate using SSI protocols.
Table 33. Necessary Parameters for 8285 #2
Parameter | Value | Comments |
|
|
|
IP address | 9.100.86.151 |
|
|
|
|
Subnet mask | FF.FF.FF.C0 | Must be entered in dotted |
|
| hexadecimal. |
|
|
|
Default | 9.100.86.130 |
|
gateway |
|
|
|
|
|
ATM prefix | 3999999999999900009999 | First |
|
| match 8285 #1. |
|
|
|
ACN | 01 | 12th byte. Must match 8285 |
|
| #1. |
|
|
|
ATM hub | 02 | 13th byte. Must be unique |
number |
| within cluster. |
|
|
|
ATM ESI | 999999999902 | |
|
|
|
ATM selector | 00 | Has significance only to local |
|
| workstation. |
|
|
|
ARP server | 08005A99029F | |
ESI |
|
|
|
|
|
ARP server | 00 | Must explicitly match the ARP |
selector |
| server ′ s value. |
|
|
|
We configure the second switch just as we did the first one, however for the sake
of brevity, we show only the commands that are new for thi s scenario.