This soft copy for use by IBM employees only.

First, if you can access the IBM 8285 using the console interface, it means the IBM 8285 microcode works fine. The level and status of the IBM 8285 microcode can be checked using the SHOW DEVICE command. And the SHOW MODULE command can be used to check the FPGA picocode level and status of an ATM blade.

Figure 37 shows the console screen when the SHOW MODULE command is issued to check the physical installation status.

 

￿

 

 

 

￿

 

8285> show module all ￿1￿

 

 

 

 

 

 

 

 

Slot Install Connect Operation

General Information

 

 

--------------------------------------------------------------------------

 

 

 

1

Y

Y

Y

8285 Nways ATM Workgroup Switch ￿2￿

 

 

2

Y

n

n

- ￿2￿

 

 

3

n

n

n

-

 

 

 

4

n

n

n

-

 

 

 

 

8285> set module 2 connected enable ￿3￿

 

 

 

Slot 2:Module set

 

 

 

 

 

 

8285> show module all ￿4￿

 

 

 

 

 

 

Slot Install Connect Operation

General Information

 

 

--------------------------------------------------------------------------

 

 

 

1

Y

Y

Y

8285 Nways ATM Workgroup Switch

 

 

2

Y

Y

Y

8285 ATM Wan module with E3 + E3 Ports ￿5￿

 

 

3

n

n

n

-

 

 

 

4

n

n

n

-

 

 

 

￿

8285>

 

 

 

 

￿

 

 

 

 

 

 

 

Figure 37. Sample Screen to Check the Physical Installation

Notes

￿1￿ The SHOW MODULE command is issued to the IBM 8285 base unit that has an expansion unit with a WAN module connected to it.

￿2￿ All status indicators of the Base Unit (install, connect and operation) are Y (yes) but only the install status of module installed in the expansion unit is Y. This is normal.

If you dont have the expansion unit, only the first line, starting with slot number 1, is displayed.

￿3￿ To change the other status indicators, issue the SET MODULE command.

￿4￿ The SHOW MODULE command is issued after the SET MODULE command.

￿5￿ All of the status indicators of the module have become Y. This means the physical installation has been done successfully. If any status does not become Y, check the physical installation procedure.

108ATM Workgroup Solutions: Implementing the 8285 ATM Switch

Page 124
Image 124
IBM SG24-4817-00 manual Sample Screen to Check the Physical Installation