IBM SG24-4817-00 manual Access read-write Status mandatory

Models: SG24-4817-00

1 316
Download 316 pages 44.88 Kb
Page 275
Image 275

This soft copy for use by IBM employees only.

ACCESS read-write

STATUS mandatory

DESCRIPTION

Writing a reset(2) will reset every module in the stack

without changing the current configuration and will zero all counters.″

::= { conc 2 }

concNumSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory

DESCRIPTION

The number of slots in this concentrator. This value is the sum total of all payload slots plus any slots reserved for controller modules. For example, for an IBM 8260 agent

operating in a 17-slot IBM 8260 hub, this object will have the value 19 (17 payload slots plus 2 controller slots).″

::= { conc 3 }

concProfile OBJECT-TYPE

SYNTAX OCTET STRING (SIZE(1..3)) ACCESS read-only

STATUS mandatory

DESCRIPTION

″A bit string containing always 00 00 00.″ ::= { conc 4 }

concDescr OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..128)) ACCESS read-only

STATUS mandatory

DESCRIPTION

″A textual string containing information about the hub type.″ ::= { conc 5 }

--The env Group

--This group represents the concentrator′ s environment. It is available

--from agents that are acting as a concentrator master.

envTempStatus OBJECT-TYPE SYNTAX INTEGER { okay(1),

extremeTemp(2),

warning(3)

}

ACCESS read-only STATUS mandatory

DESCRIPTION

The overall temperature status for this concentrator. This object′ s value is an aggregate of all the temperature probes in the concentrator, such that, when at least one probe reports extreme temperature, this object will have the value extremeTemp(2). This object will have the value warning(3)

prior to reporting the value extremeTemp(2) as a means of warning of a possible hub overheat condition.″

Appendix E. IBM ATM Campus Switch Private MIBs 259

Page 275
Image 275
IBM SG24-4817-00 manual Access read-write Status mandatory