This soft copy for use by IBM employees only.

ocPowerOutputWattageAvailable OBJECT-TYPE SYNTAX Gauge

ACCESS read-only STATUS mandatory

DESCRIPTION

In hundredths of a Watt (1/100 Watt), the wattage available to power-up modules. If power fault-tolerant

mode is enabled (when it was previously disabled), this object′ s value is decreased by the amount of power reserved

for the voltage line. If power fault-tolerant mode is disabled (when it was previously enabled), this object′ s

value is increased by the amount of power that is returned to the available power budget for the voltage line.″

::= { ocPowerOutputEntry 5 }

ocPowerOutputUnmanagedWattageAlloc OBJECT-TYPE SYNTAX Gauge

ACCESS read-only STATUS mandatory

DESCRIPTION

In hundredths of a Watt (1/100 Watt), the wattage

reserved for modules that are not power-manageable. This value 0 is always returned.″

::= { ocPowerOutputEntry 6 }

--

--Module power configuration

ocPowerSlotTable OBJECT-TYPE

SYNTAX SEQUENCE OF OcPowerSlotEntry ACCESS not-accessible

STATUS mandatory

DESCRIPTION

A table that contains power management information for each non-empty, payload slot in the hub. Note that for multi-slot IBM 8260 modules, there is one point of power management contact and control. Hence, only

the leftmost slot is represented in this table.″ ::= { ocPower 3 }

ocPowerSlotEntry OBJECT-TYPE SYNTAX OcPowerSlotEntry ACCESS not-accessible STATUS mandatory

DESCRIPTION

A list of power management information for each payload slot in the hub containing an 8260 module.″

INDEX { ocPowerSlotIndex } ::= { ocPowerSlotTable 1 }

OcPowerSlotEntry ::=

SEQUENCE { ocPowerSlotIndex

INTEGER, ocPowerSlotClass

INTEGER,

ocPowerSlotAdminStatus

INTEGER,

268ATM Workgroup Solutions: Implementing the 8285 ATM Switch

Page 284
Image 284
IBM SG24-4817-00 manual OcPowerOutputWattageAvailable OBJECT-TYPE Syntax Gauge