This soft copy for use by IBM employees only.

chassisChange TRAP-TYPE

ENTERPRISE node

DESCRIPTION

A chassisChange trap is used to indicate that a configuration

change has occurred. The actual variables that changed are included in the variables section of the PDU.″

::= 107

chassisModuleDown TRAP-TYPE

ENTERPRISE node

DESCRIPTION

A chassisModuleDown trap indicates that management communications with a slot has been

broken. This event usually occurs when a module has been physically removed from the concentrator. However, it

is possible for this event to occur when the particular module fails.″

::= 116

chassisModuleUp TRAP-TYPE

ENTERPRISE node

DESCRIPTION

A chassisModuleUp trap indicates that management communications with a slot has been

established. This event usually occurs when a module has

physically been inserted into the concentrator. The variable chipModType indicates the module type inserted.″

::= 117

END