This soft copy for use by IBM employees only.

DESCRIPTION

The version and release number for this module

firmware (microcode).″ ::= { moduleEntry 5 }

moduleHardwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory

DESCRIPTION

The Part Number (P/N) and Engineering Change (EC) level for this module and Plant Location.″

::= { moduleEntry 6 }

moduleAdminState OBJECT-TYPE SYNTAX INTEGER {

ready (1), reset (2)

}

ACCESS read-write STATUS mandatory

DESCRIPTION

The administrative state of this module.

On an 8260, when set to reset for an entry associated to

the active switch/control point module, the whole atm subsystem is reset and a switch swap over may occur if the backupMode criterium has been changed since the last reset.

When set to reset for an entry associated to a module which is not the active Control Point/Switch module, only this module is reset.″

::= { moduleEntry 7 }

moduleOperState OBJECT-TYPE SYNTAX INTEGER {

unknown (1), operational (2), not-operational (3), standby (4), maintenance (5), testing (6), switch-error (7), incompatible-level (8)

}

ACCESS read-only STATUS mandatory

DESCRIPTION

The operational state of this module. When unknown, the module cannot be accessed by the Control Point.

When operational, the module is operational.

When not-operational, the module is not operational. When standby, the module is a redundant switch module ready to be used.

When maintenance, the module is a redundant switch module currently in maintenance mode.

When testing, the module is a redundant switch module currently running diagnostics.

When switch-error, the module is a redundant switch module not operational, not ready to be used because an error

204ATM Workgroup Solutions: Implementing the 8285 ATM Switch

Page 220
Image 220
IBM SG24-4817-00 manual Description