This soft copy for use by IBM employees only.

8285 LEC parameters

8285 Integrated LES parameters ATM module and port parameters

The parameters we use in our example are listed in Table 36.

Table 36. Necessary Parameters for 8285#1

Parameter

Value

Comments

 

 

 

ATM Address

 

 

 

 

 

ATM Prefix

3999999999999900009999

First 11 bytes of address

 

 

 

ACN

01

12th byte, should not be 0

 

 

 

HN

09

13th byte, should not be 0

 

 

 

ESI

999999999901

6-byte MAC address

 

 

 

SEL

00

20th byte

 

 

 

8285 Integrated LES parameters

 

 

 

 

Server ID

1

 

 

 

 

ELAN type

Ethernet

 

 

 

 

Max # of

64

 

clients

 

 

 

 

 

Max SDU size

1516

Default

 

 

 

ELAN name

IBM_ETHERNET_LAN1

Default

 

 

 

8285 LEC parameters

 

 

 

 

ELAN type

Ethernet

 

 

 

 

Ethernet type

DIX

 

 

 

 

IP address

9.100.86.200

 

 

 

 

Subnet Mask

FF.FF.FF.C0

 

 

 

 

Default

0.0.0.0

Not specified because not used

Gateway

 

in this configuration

 

 

 

MAC address

0200CCCCCCCC

Canonical format

 

 

 

Associated

39999999999999000099

Use pre-defined LES ATM

LES or LECS

99010999999999990102

address (NO_LECS_WITH_LES)

ATM address

 

 

 

 

 

The commands we need are:

SET DEVICE ATM_ADDRESS

SET LAN_EMUL SERVER

SET DEVICE LAN_EMULATION_CLIENT

SET PORT

The SET DEVICE ATM_ADDRESS command causes the ATM subsystem to reset, so you have to save the configuration using SAVE ALL command if there are unsaved parameters.

Figure 44 on page 138 is an annotated transcript of the commands used to configure and test our simple LANE network.

Chapter 7. IBM 8285 Configuration 137

Page 153
Image 153
IBM SG24-4817-00 manual Commands we need are