This soft copy for use by IBM employees only.

port has been detected by the physical layer. The port is enabled.

-in-service: the remote device successfully acknowledges ILMI polling requests and SVC registration

-pvcOnly: the remote device succesfully acknowledges ILMI polling requests but it rejects the ATM prefix registration. Only PVCs are supported.

-misConfigured: an SSI to UNI or an SSI to NNI configuration has been detected

-wrongNetworkPrefix: the switches on each end of an SSI link have incompatible network prefixes (the 12 first bytes have different values)

-wrongNodeNumber: the switches on each end of an SSI link have the same ATM node Numbers.

-failing-line: the port is enabled and a invalid

signal is detected on the line - disabled-failing: the port is disabled and an

anomaly is detected, either internal or external.

- wrap-no-signal: the port is internally wrapped so that

all the traffic received on the attached line is returned unchanged on the line.

No activity is detected at the physical layer.

- wrap-idle: the port is internally wrapped so that

all the traffic received on the attached line is returned unchanged on the line and

a valid signal is detected on the line.

-wrap-failing-internal: an internal failure has been detected when the port has been turned into the wrap-reply state. The actual state of the port is undefined.

-wrap-failing-line: the port is internally wrapped so that all the traffic received on the attached line is returned unchanged on the line and an invalid signal is detected

on the line.

-idle-no-bandwidth: the port is enabled and activity

from the remote device is detected but there is not enough bandwidth to operate the port with its current configuration. This state does not apply for UNI port.

-idle-internal-error: The port is enabled and activity from the remote device is detected but an internal error has occurred during

the checking of the bandwidth configuration. This may be due to a lack of connection ressources in the module where this port is located.

-disabled-no-bandwidth:

the enabling of the port is not possible because

there is not enough bandwidth to operate the port with its current configuration. This state applies only for a SSI port.

- wrap-far-end-no-signal:

the port is in wrap-far-end

mode, ie the remote end of the line is

210ATM Workgroup Solutions: Implementing the 8285 ATM Switch