port has been detected by the physical layer. The port is enabled.
-
-pvcOnly: the remote device succesfully acknowledges ILMI polling requests but it rejects the ATM prefix registration. Only PVCs are supported.
-misConfigured: an SSI to UNI or an SSI to NNI configuration has been detected
-wrongNetworkPrefix: the switches on each end of an SSI link have incompatible network prefixes (the 12 first bytes have different values)
-wrongNodeNumber: the switches on each end of an SSI link have the same ATM node Numbers.
-
signal is detected on the line -
anomaly is detected, either internal or external.
-
all the traffic received on the attached line is returned unchanged on the line.
No activity is detected at the physical layer.
-
all the traffic received on the attached line is returned unchanged on the line and
a valid signal is detected on the line.
-
-
on the line.
-
from the remote device is detected but there is not enough bandwidth to operate the port with its current configuration. This state does not apply for UNI port.
-
the checking of the bandwidth configuration. This may be due to a lack of connection ressources in the module where this port is located.
-
the enabling of the port is not possible because
there is not enough bandwidth to operate the port with its current configuration. This state applies only for a SSI port.
-
the port is in
mode, ie the remote end of the line is