This soft copy for use by IBM employees only.
ocPowerOutputWattageAvailable Gauge,
ocPowerOutputUnmanagedWattageAlloc Gauge
| } |
|
|
ocPowerOutputType |
|
| |
SYNTAX INTEGER { |
|
| |
| plusFiveVolt(1), | ||
| minusFiveVolt(2), | Volt | |
| plusTwelveVolt(3), | Volt | |
| minusTwelveVolt(4), | Volt | |
| plusTwoVolt(5) | Volt | |
| } |
|
|
ACCESS |
|
| |
STATUS | mandatory |
|
|
DESCRIPTION |
|
|
″Identifies the power (voltage) line type for which this entry contains power budget information.″
::= { ocPowerOutputEntry 1 }
ocPowerOutputVoltageLevel
ACCESS
DESCRIPTION
″In millivolts (1/1000 Volt), the actual voltage level
for this voltage type as sensed on the backplane. This voltage is supplied by all operational power supplies.″
::= { ocPowerOutputEntry 2 }
ocPowerOutputWattageCapacity
ACCESS
DESCRIPTION
″In hundredths of a Watt (1/100 Watt), the maximum
wattage for the voltage line that is output by all operational power supplies combined.″
::= { ocPowerOutputEntry 3 }
ocPowerOutputWattageConsumed
ACCESS
DESCRIPTION
″In hundredths of a Watt (1/100 Watt), the wattage
consumed by all hub modules. For a given voltage line, this object′ s value is the sum total of the power consumed by the hub itself, the Controller Modules
and all
If power
If power
by the amount of power that is returned to the available power budget for the voltage line.″
::= { ocPowerOutputEntry 4 }
Appendix E. IBM ATM Campus Switch Private MIBs 267