Display Detail Report for Resource

 

 

 

 

 

 

 

Serial

Resource

 

Name

Type

Model

Number

Name

 

 

LWS

7209

000

00-00000

CTL01

 

Log ID . . . .

. . . . . :

0102000A

Sequence

:

6308

 

Date

. . . . . :

08/23/93

Time

:

12:30:00

 

Reference code

. . . . . :

102E

Secondary code . . . .

:

00000000

 

Table ID . . .

. . . . . :

B600FA00

IPL source/state .

. . :

A/1

Class

. . . . . :

Permanent

 

 

 

 

Description . .

. . . . . :

Battery power unit needs service.

 

 

 

Out of alternate sectors

for disk storage.

 

F3=Exit

F6=Display hexadecimal report

F9=Address Information

F10=Previous detail report

F12=Cancel

Figure 50. Example Detail Report

For more information on resource names, see “Resource names” on page 242.

Resource type, model, and location

The Type, Model, and Physical location fields provide entry information that can assist in problem analysis. The Physical location field contains the location of the resource that is most closely related to the entry. You can also use the address information function (see “Address information function” on page 106) and the logical address (see “Logical address format” on page 114) to gather details about the resource type, model, and location. For more information on resources, see Chapter 2, “Hardware Service Manager” on page 45.

Note: When the I/O processor is not known for I/O bus entries, press the Address Information function key from the Display Detail Report for Resource display to view the configuration information. Use the configuration information to determine the card position of the I/O processor.

Class

The Class field describes the event that logged the entry. Some events are related to errors that were detected, and some events are activities that normally occur. The meaning of Class varies depending on the system, subsystem, or device against which the entry was logged. Perform a service action only when directed by a system operator message, the directed service procedures, or your next level of support.

The events that can appear in the Class field are:

Data protection lost

An error occurred in hardware that has data protection (mirroring). This function continues to operate, but service is required. A second failure in this area might result in the loss of the function and the data.

Description

Explains the reference code (appears only for OS/400).

Dump A storage dump was taken.

112Service Functions V5R2

Page 126
Image 126
IBM SY44-5902-05 manual Resource type, model, and location, Class, Data protection lost