IBM SY44-5902-05 manual Models 270, 8xx, SB2, and SB3, Example SRC record structure all models

Models: SY44-5902-05

1 358
Download 358 pages 16.87 Kb
Page 206
Image 206

more information on stage three formats or hardware stages, see Appendix C of iSeries Licensed Internal Code Diagnostic Aids - Volume 1.

The SRC record structure provides information about the machine at the time of the failure.

For models 150, 170, 250, 4xx, 50x, 51x, 530, 53S, 6xx, 7xx, SB1, S10, S20, S30, and S40, SRCs may consist of up to nine “data words”. A word (a word = 4 bytes of sequential data) consists of 8 hexadecimal characters (0-9 or A-F). The function number corresponds to the function on the control panel or Work with Partition Status display that shows the specific word of the SRC. For these systems the word number corresponds to the function number. For example, only word 1 (previously called word 11 to match the function number) of the SRC appears in function 11. See Table 37.

Models 270, 8xx, SB2, and SB3

Models 270, 8xx, SB2, and SB3 have a larger control panel than previous models. They can display up to four words at a time. In addition, the first word of the SRC can consist of ASCII or hexadecimal characters. The other eight words of the SRC still consist of hexadecimal data. Function 11 still displays the first word of the SRC, which can contain 8 to 32 characters (expanded word 1). In the Product Activity Log (PAL) and other software displays, the SRC appears much like it does for earlier releases, except for the possibility of word 1 containing up to 32 characters. Words display as a number from 1 to 9 instead of 11 to 19, thus disassociating the word number from the function number. Refer to Chapter 3, “Product Activity Log” on page 99 for more information on the PAL and SAL. Refer to Table 37 to see the new format.

Example SRC record structure (all models)

Table 37. Example SRC record structure

Models 150, 170,

Models 270, 8xx, SB2,

 

 

250, 4xx, 50x, 51x,

and SB3

 

 

 

530, 53S, 6xx, 7xx,

 

 

 

 

SB1, S20, S30, and

 

 

 

 

S40

 

 

 

 

 

 

 

 

 

Function

Function

Characters

Word

Description

 

 

 

 

 

11

11

1–8

1

The leftmost 4 characters

 

 

 

 

displayed describe the reference

 

11

9–32

Extended

code identifier (usually the unit

 

reporting error). The rightmost 4

 

 

 

Word 1

 

 

 

characters are the unit reference

 

 

 

 

 

 

 

 

code.

12

12

1–8

2

Displays general system state

 

 

 

 

information.

13

12

9–16

3

Displays additional information

14

12

17–24

4

about the failure, such as

15

12

25–32

5

location of the unit, sense data,

16

13

1–8

6

and serial number.

Note: For some systems, Word

17

13

9–16

7

14 displays the unit address in

18

13

17–24

8

eight digits.

19

13

25–32

9

 

 

 

 

 

 

192Service Functions V5R2