IBM SY44-5902-05 manual Hex Digit IPL State Description

Models: SY44-5902-05

1 358
Download 358 pages 16.87 Kb
Page 209
Image 209

6Debug data exists, full dump (main storage and hardware data)

7Debug data exists, extended dump (main storage, hardware data, and destructive data)

8Debug data exists; dump failed after writing segment identifier (SID) 82 to disk

9No debug data exists, destructive data access failed

ANo debug data exists, main storage dump failed

BNo debug data exists, destructive and main storage access failed

CNo debug data exists, partial dump failed

DNo debug data exists, hardware dump failed

ENo debug data exists, full dump failed

FNo debug data exists, extended dump failed

IPL State Indicator (I): The second digit that is displayed in Word 2 indicates how far the IPL went on before the system displayed the SRC. The indicator has the following meanings.

Hex Digit

IPL State Description

0Service processor IPL from start-up code in progress

1IPL from random access memory (RAM) is running

2Service processor task initialized

3LIC initialization completed

4Operational load of LIC is complete

5Bus manager initialized

6Main Storage initialization is complete

7Load Source DASD connection established

8Dedicated Service Tool (DST) or limited paging available

9Storage management directories verified

AAuthority structures verified

BIndexes verified

CDatabase verified

DLIC hand-off to operating system

EIPL is complete to sign on display

FPower down attempted

IPL Type Last Initiated Indicator (G): The third hexadecimal digit that Word 2 displays indicates the IPL type (IPL mode and environment) of the last IPL performed, or the IPL running at the time of the failure. The IPL type for models 150, 170, 250, 4xx, 50x, 51x, 530, 53S, 6xx, 7xx, SB1, S20, S30, and S40 is coded as shown in Table 39 on page 196. The IPL type for models 270, 8xx, SB2, SB3, and 890, is coded as shown in Table 40 on page 196.