IBM SY44-5902-05 manual Changing the address, For PowerPC-based IOPs Setting the ww Position

Models: SY44-5902-05

1 358
Download 358 pages 16.87 Kb
Page 148
Image 148

For PowerPC-based IOPs, you set all four bytes of the address (wwxx yyzz). Set ww with the first use of function 59. Set xx with the second use of function 59. Set the

yywith Function 60 and zz with Function 61 as described in “Changing the address”.

Changing the address

For PowerPC-based IOPs: Setting the ww Position:

1.Press the Increment () or Decrement () switch until 59 appears in the Function display.

2.Press Enter on the control panel; ** appears next to the function number.

3.Press the Increment () or Decrement () switch until the value of ww appears next to the function number.

4.Press Enter on the control panel.

5.Press the Increment () or Decrement () switch until ** appears next to the function number (59**).

6.Press Enter on the control panel.

To continue, follow the steps in “For Motorola** 68020 Processor-based IOPs” below.

For Motorola** 68020 Processor-based IOPs: Setting the xx Position:

1.Press the Increment () or Decrement () switch until 59 appears in the Function display.

2.Press Enter on the control panel; ** appears next to the function number.

3.Press the Increment () or Decrement () switch until the value of xx appears next to the function number.

4.Press Enter on the control panel.

5.Press the Increment () or Decrement () switch until ** appears next to the function number (59**).

6.Press Enter on the control panel.

Setting the yy Position:

7.Press the Increment () or Decrement () switch until 60 appears in the Function display.

8.Press Enter on the control panel; ** appears next to the function number.

9.Press the Increment () or Decrement () switch until the value of yy appears next to the function number.

10.Press Enter on the control panel.

11.Press the Increment () or Decrement () switch until ** appears next to the function number (60**).

12.Press Enter on the control panel.

Setting the zz Position:

13.Press the Increment () or Decrement () switch until 61 appears in the Function display.

14.Press Enter on the control panel; ** appears next to the function number.

15.Press the Increment () or Decrement () switch until the value of zz appears next to the function number.

16.Press Enter on the control panel. Record the data from the display as the base address.

134Service Functions V5R2

Page 148
Image 148
IBM SY44-5902-05 manual Changing the address, For PowerPC-based IOPs Setting the ww Position, Setting the yy Position