Table 8. Hexadecimal dump byte assignments for non-keyed data (continued)

 

 

 

Hexadecimal offset

Length in bytes

Description

00EE

4

Component ID

00F2

8

Version/Release/Modification

00FA

50

Resource paths

012C

10

Power controlling system (PCS) name

0136

10

Power controlling system (PCS) serial

 

 

number

0140

10

Resource at log time

014A

4

Frame ID

014E

2

EIA location

0150

12

Part number

015C

1

Protocol

015D

1

Format of data

015E

1

Delayed reporting

015F

1

Signal event

0160

4

Secondary code

0164

2

Flags

0166

2

State at log time

0168

4

Power controlling system (PCS) type

016C

4

Power controlling system (PCS) model

0170

8

Reserved

0178

2

Component record format

0176

2

Statistics offset

017C

4

Component data length

 

Table 9. Hexadecimal dump byte assignments for variable component specific data

 

 

 

Hexadecimal Offset

Length in Bytes

Description

0180

 

This field is different for each log entry and

 

 

is intended for engineering use only.

 

 

However, see “More information from

 

 

hexadecimal reports” for examples of how

 

 

the hexadecimal information can be

 

 

interpreted for a D-IPL.

 

 

 

More information from hexadecimal reports

You can get additional information for IOP 90xx reference code product activity log entries at DST by using a D-IPL.

Note: The term I/O processor may indicate an IOP or an IOA.

Below are examples of how to interpret hexadecimal information for a D-IPL. Note: Formatting is available (F4=Additional Information) for IPL from disk (A- or

 

 

B-IPL). Formatting is not available in DST from a D-IPL.

 

Use the information below and the example displays on the following pages to

 

interpret the hexadecimal dump information that begins at offset hex 000180. If the

 

characters at offset 00019F are:

 

01

Device formatting

 

02

Array Member formatting

 

03

Configuration formatting

04

Array addendum formatting

Chapter 3. Product Activity Log 117

Page 131
Image 131
IBM SY44-5902-05 manual More information from hexadecimal reports