IBM SY44-5902-05 manual Example Display HSL System Information display

Models: SY44-5902-05

1 358
Download 358 pages 16.87 Kb
Page 165
Image 165

1.From the Logical Hardware Resources display, select the Display System Information option.

Display HSL System Information

Local system type . . . . : 9406

Local system serial number: 10-0033333

HSL loop number . . . . . . . . . . . . . . . . . . . . . . . . : 257

HSL I/O Bridge

resource

 

 

 

 

 

Type-model .

. . . . :

1999-999

Status

:

Operational

Serial number

. . . .

:

21-1111111

Part number

:

111111111111

Resource name

. . . .

:

BC06

Mode

:

Switchable

SPCN system information

 

 

 

 

 

System type .

. . . .

:

9406

 

 

 

System serial number

:

10-0033333

Owner

 

 

Alternate system information

 

 

 

System type .

. . . .

:

9406

 

 

 

System serial

number

:

10-1234567

 

 

 

F3=Exit F6=Print F11=Display port information F12=Cancel

Figure 68. Example Display HSL System Information display

2.Record the local system type and local system serial number with the information you recorded for the system’s HSL I/O bridge resource name, HSL loop number, type-model, and serial number (See the procedure “Determining if a tower is configured as switchable” on page 149).

3.Record the power controlling System type and System serial number from the SPCN System Information field. The power controlling system’s type, model, and five digits of the serial number are shown in the second line of the tower’s panel.

4.Record the System type and System serial number from the Alternate System Information field. This is the system that the ownership of resources in the tower can be switched to for any resources in the tower that are configured as switchable.

5.Are the Local system type and Local system serial number the same as the SPCN system type and SPCN system serial number?

v Yes = The local system is the power controlling system for the tower. You can perform service procedures requiring power off and power on of the tower from the local system if the local system is also the owner of the switchable resources in this tower. Continue with the next step of this procedure.

vNo = The local system is not the power controlling system for the tower. Service procedures requiring power off and power on of the tower cannot be performed from the local system. Continue with the next step of this procedure.

6.Record which system is the current owner of switchable resources in the tower.

Note: The current owner is determined by locating the term Owner which will be displayed with either the SPCN system information or the Alternate system information. From the Owner system, you can use the Hardware Service Manager (HSM) to work with switchable resources in the tower,

Chapter 4. Service Reference Procedures 151