IBM SY44-5902-05 manual Action to be performed, Time delay needed in minutes

Models: SY44-5902-05

1 358
Download 358 pages 16.87 Kb
Page 74
Image 74

Usually, the serial number information is not needed, but if the server detects a duplicate Frame ID in your Device Concurrent Maintenance request, you will be returned to this same screen with a blank serial number field. Simply put the serial number for the CEC that originally controlled the frame into this field. This serial number can be found in the Service Action Log FRU Details or in Hardware Service Manager information screens.

Disk Unit Hardware Resource Information Details

Type

: 6713

Model

: 050

Level

: 3

Serial Number

: 68-xxxxx

Resource Name

: DD037

Physical location:

 

Frame ID

: 1

Card position

:

Device position

: L01

Figure 16. Example Disk Unit Hardware Resource Information Details display

In Figure 16, the disk unit has a Frame ID of 1, a Position of L01, and a Resource Name of DD037. To perform device concurrent maintenance on this unit, fill in the information as shown in Figure 17. Press Enter. If the device is unable to report in or you are installing a device into an empty slot, use Frame ID and Position instead of Resource Name.

Action to be performed

If removing the device, specify 1. If inserting the device, specify 2.

Time delay needed in minutes

Enter 00 in this field if you do not want any delay before the process begins. If you enter a value in this field, the device will wait that long after you press Enter to begin the operation. Typically you will enter a value if the device is at a different location and it will take you a while to get to that location. The device might be in a different room, for example.

Figure 17. Example Device Concurrent Maintenance with data for Frame ID and Position fields

60Service Functions V5R2

Page 74
Image 74