Display HSL Information

HSL loop number . . . . . . . . . : 257

HSL I/O bridge resource Type-model . . . : 1999-999 Serial number . . : 21-1111111 Resource name . . : BC06

Status . . . . . : Operational Part number . . . : 111111111111 Mode: Switchable

Leading port to next resource . . .

. . . . . . :

 

Link status . .

:

Operational

Link type

. . . : Copper

Type of connection

. . . . . . .

. . . . . . :

Internal

Trailing port from previous resource

. . . . . :

A1

Link status . .

:

Disabled

Link type . .

. : Optical

Type of connection

. . . . . . . .

. . . . . :

External

F3=Exit F6=Print F7=Follow trailing port F8=Follow leading port

F9=Include non-reporting resources F11=Display system information

F12=Cancel

Figure 67. Example Display High Speed Link (HSL) Information display

8.From the Display HSL Information screen select F8 (Follow leading port). This changes the information to that of the next resource on the HSL loop starting from cable port 0. Smaller system models may have an internal I/O resource before going to the first I/O tower on the HSL loop.

9.Select F8 (Follow leading port) to display the HSL information. For each I/O tower or system tower along the HSL Loop, at the Display HSL Information display, locate the Mode information of the resource.

Note: If you cannot locate the Mode information, then this HSL resource is not part of a Cluster Resource Group (CRG) and the tower where this HSL I/O bridge resource is located cannot be configured as switchable.

10.Is the mode listed as Private or is the mode not displayed for this resource?

vYes: The tower where this HSL I/O bridge resource is located cannot be configured as switchable. Select F8 again to procede to the next tower.

vNo: The HSL I/O bridge resource has a mode of switchable. The tower is configured as a switchable tower. Continue with the next step of this procedure.

11.Record the HSL loop number, the type-model, and the serial number of the HSL I/O bridge resource.

Notes:

a.You will need the type-model and serial number to identify the HSL I/O bridge on the other system in the HSL Opticonnect loop.

b.When there are multiple towers on the HSL OptiConnect loop, care must be taken to match the physical tower to the HSL Information screen in order, starting from port 0 on the system. Keep in mind that on smaller systems there may be an internal resource before getting to the external cable port.

Determining the power controlling system of a tower

You can determine the power controlling system of a tower by performing the following procedure.

150Service Functions V5R2

Page 164
Image 164
IBM SY44-5902-05 manual Determining the power controlling system of a tower