Table 15. IPL speeds (continued)

IPL speed

Action or description

Details

 

 

 

S:

Slow override for one IPL.

Full hardware diagnostics run. Use

 

 

whenever hardware is changed, for

 

 

intermittent hardware failure, and on the

 

 

first installation IPL. The following

 

 

diagnostics are run:

 

 

v Main storage tests.

 

 

v CEC Inter-chip interface tests (wire test).

 

 

v Extended Logical Built-in Self Tests.

SE:

Hardware upgrade.

Support-directed procedure only.

 

 

 

V=F:

Use system-defined speed.

Fast IPL set by system value (displayed at

 

 

function 01).

 

 

 

V=S:

Use system-defined speed.

Slow IPL set by system value (displayed at

 

 

function 01).

 

 

 

V

Fast IPL or slow IPL set

Function 02 selection or the system default

 

by the system value

at each IPL.

 

(selected at function 02).

 

 

 

 

Control Panel Functions (Models 150, 170, 250, 4xx, 50x, 51x, 530, 53S, 6xx, 7xx, SB1, and Sxx)

The control panel functions and descriptions are listed in Table 16. For more details about the functions, begin at “Control panel function descriptions (Models 150, 170, 250, 4xx, 50x, 51x, 530, 53S, 6xx, 7xx, SB1, and Sxx)” on page 162.

Notes:

1.Some control panel functions might not be available on all system types.

2.The x can be any number 0 through 9, any letter A through F, or a blank.

3.If the customer was performing the function, find out why the customer selected the function and verify whether it is complete.

4.If you cannot change the Function/Data display or complete the selected function, go to “Starting Point for All Problems” in the Problem Analysis information for your system.

Table 16. Control panel (8-character) function codes

Function code

Function selected

 

 

01

Pressing the Enter button toggles between:

 

1.

Display the currently selected IPL type (and logical key mode on some system

 

 

types).

 

2.

Display the currently selected IPL speed override for the next IPL.

 

 

 

02

1.

Pressing the Enter button once allows selection of the IPL type (and logical key

 

 

 

mode on some system types).

 

2.

When the system power is off, pressing the Enter button twice allows selection

 

 

of an IPL speed override for the next IPL.

 

 

03

Start an IPL to load the system. The IPL uses the selected IPL options.

 

 

04

Lamp test; all displays and indicators will be switched on.

 

 

05

System Power Control Network (SPCN) system reference code (SRC); displays an

 

SRC on the control panel.

 

 

 

160Service Functions V5R2

Page 174
Image 174
IBM SY44-5902-05 manual Function code Function selected