Table 38. General System Reference Codes (SRCs) (continued)

Problem

SRC

Description

 

B9xx xxxx

Operating system machine check (See iSeries OS/400 Diagnostic

 

 

Aids)

Operator

A1xx xxxx

Operation interruption by service processor

intervention

 

 

 

A6xx xxxx

Operation intervention by LIC

 

A9xx xxxx

Operation interruption by operating system

IPL status

C1xx xxxx

IPL status for the service processor

 

C2xx xxxx

General status for normal LPAR power on

 

C3xx xxxx

IPL status for the system processor

 

C5xx xxxx

IPL status for system hardware initialization

 

C6xx xxxx

IPL status for LIC

 

C6xx 4400

Automatic main storage dump recovery (IPL) status

 

C6xx 441x

Automatic power failure recovery (IPL) status

 

C6xx 4500 through 4509

DST IPL status

 

C9xx xxxx

IPL status for OS/400 operating system program. See iSeries

 

 

OS/400 Diagnostic Aids

General status

D1xx xxxx

General status for the service processor

 

D2xx xxxx

General status for normal LPAR power off

 

D6xx xxxx

General status for Main Storage Dump Manager, LIC run-time

 

 

status, or LIC power off

 

D9xx xxxx

Power down status for OS/400 operating system program. See

 

 

iSeries OS/400 Diagnostic Aids

 

 

 

Word 2 - System status information

Word 2 provides a fixed location for information common to all SRCs shown on the control panel. It is available for all SRC formats except power and control panel. The service processor provides this information at the time the SRC is displayed to the panel.

Notes for status indicators listed below:

1.For the coding of M, Main storage dump indicator, see “Main Storage Dump Indicator (M)”.

2.For the coding of I, IPL state indicator, see “IPL State Indicator (I)” on page 195.

3.For the coding of G, IPL type last initiated indicator, see “IPL Type Last Initiated Indicator (G)” on page 195.

Status indicators

Main Storage Dump Indicator (M): The first hexadecimal digit that is displayed in Word 2 indicates whether the system started a main storage dump and if it was successful. The indicator has the following meanings:

M Description

0Dump was not initiated

1Debug data exists, destructive data only

2Debug data exists, main storage only

3Debug data exists, main storage and destructive data only

4Debug data exists, partial dump (hardware data only)

5Debug data exists, hardware and destructive data only

194Service Functions V5R2

Page 208
Image 208
IBM SY44-5902-05 manual Word 2 System status information, Status indicators