For powered-off systems without a keystick, function 02 is used to select the IPL type and IPL speed indicators. Table 22 shows an example of the sequence for powered-off systems without a keystick.

Table 22. Function 02 Select IPL Type and IPL Speed on Systems without an Electronic Keystick

Function/data

Action or description

 

 

 

02

_ _ _ _ _ _

Use the Increment or Decrement buttons to scroll to Function 02.

 

 

 

02

_ _ _ A _ N

Press Enter once to start function 02. Use the Increment or

 

 

Decrement buttons to scroll through valid IPL type and logical key

 

 

mode combinations (A_N, B_N, C_N, D_N, A_M, B_M, C_M, D_M).

 

 

 

 

 

Press Enter to save the selected IPL type and key mode

 

 

combination and exit Function 02.

 

 

 

 

 

Use the Increment or Decrement buttons to scroll to Function 02.

 

 

 

02

_ _ _ _ V _

Press Enter twice in a row to select the IPL speeds. Use the

 

 

Increment or Decrement buttons to scroll through the IPL speeds.

 

 

 

 

 

Press Enter to select the IPL speed and exit function 02.

 

 

 

Function 03–Start IPL: Function 03 is enabled only when you select Manual mode and the system power is on.

This function starts an IPL of the selected IPL mode when you press the Enter button. All the Licensed Internal Code is loaded.

Attention: No system shutdown is performed before the IPL. The use of this function can cause loss of data.

Function 04–Lamp Test: This function shows whether any control panel indicators are burned out and whether characters that are displayed on the control panel Function/Data display are valid. When you activate this test, the following lights go on:

vOn the system control panel:

The Processor Active/Activity light

The Processor Activity Select lights

The System Attention light

The Power On light

A 5 x 7 dot pattern for each character in the Function/Data display

The Mode lights (if available)

vOn the Expansion Unit control panel (if available):

The Power On light

The SPCN Attention light

A 5 x 7 dot pattern for each character in the Data display

The lamp test continues on the system control panel until you perform another control panel function or a power procedure. The Expansion Unit control panel lamp test is only active for 25 seconds.

Use this procedure to verify that the lights on the system control panel are working correctly. If you cannot complete these steps, go to the “Starting Point for All Problems” in the Problem Analysis information for your system to start problem analysis.

Chapter 5. Control Panel Functions 165

Page 179
Image 179
IBM SY44-5902-05 manual Function/data Action or description