Table 27. Function 01 on systems with a keystick

Function/data

Action or description

 

 

0 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _

Use the Increment or Decrement buttons to

scroll to function 01.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

 

 

0 1 _ _ A _ _ _ _ _ V = F _ _ _

Valid IPL types are A, B, C, and D.

 

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Valid IPL speed displays are F, S, SE, V=F,

 

 

or V=S.

 

 

0 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _

Use the Increment or Decrement buttons to

scroll through the control panel functions.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

 

 

Function 01–Display Selected IPL Type, Logical Key Mode, and IPL Speed (on Systems without a Keystick): This function allows you to display the selected IPL type, logical key mode, and speed for the next IPL.

1.Display IPL types (A, B, C, or D).

2.Display the valid logical key modes (M or N).

3.Display IPL speed (F, S, SE, V=F, or V=S).

Table 28 shows a function 01 example on systems without a keystick.

Table 28. Function 01 on systems without a keystick

Function/data

Action or description

 

 

0 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _

Use the Increment or Decrement buttons to

scroll to function 01.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

 

 

0 1 _ _ A _ _ M _ _ V = F _ _ _

Valid IPL types are A, B, C, and D.

 

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Valid logical key modes are M and N.

 

 

Valid IPL speed displays are F, S, SE, V=F,

 

or V=S

 

 

0 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _

Use the Increment or Decrement buttons to

scroll through the control panel functions.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

 

 

Function 02–Select IPL Type and IPL Speed Override (on Systems with a Keystick): Before you can use function 02, you must have the system in Manual mode. Selection changes to IPL types can be done with the system powered on or off. Before you can select the IPL speed override, the system must be powered off.

Table 29 shows the sequence of selecting the IPL type on iSeries servers that are powered on.

Table 29. Function 02 select IPL type on powered-on systems with a keystick

Function/data

Action or description

 

 

0 2 _ _ _ _ _ _ _ _ _ _ _ _ _ _

Use the Increment or Decrement buttons to

scroll to function 02.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

 

 

0 2 _ _ A < _ _ _ _ _ _ _ _ _ _

Press Enter to start function 02. The current IPL

type is displayed with a pointer.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

 

 

0 2 _ _ B < _ _ _ _ _ _ _ _ _ _

Use the Increment or Decrement buttons to

scroll through the IPL types.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

 

 

178Service Functions V5R2

Page 192
Image 192
IBM SY44-5902-05 manual Function 01 on systems with a keystick