To update the configuration description label information in the system, perform the following procedure:

1.Perform an attended IPL:

a.Select Manual mode on the control panel.

b.Power on the system.

c.When the IPL display or the Install display appears, select the Perform an IPL option.

2.The Sign On display appears. Ask the customer to sign on as QSECOFR.

Note: It is important that you perform the following step to correctly update the device resource names.

3.At the IPL Options display:

a.Set the Start this device only option to Y (Yes).

b.Set the Define or change system at IPL option to Y (Yes).

c.Select System value commands option.

d.Select Change system values option.

e.Ensure that the system value QAUTOCFG is ’0’

f.Ensure that the system value QIPLTYPE is ’2’

Press F3 twice to continue the IPL.

Note: As the IPL continues, SRC A900 2000 appears. No action is necessary at this time.

4.Have the customer sign off after the IPL is complete.

5.Sign on to the system at the console:

v On the User line of the Sign On display, type QSRV

v On the Password line, type the default password QSRV or ask the customer for the password and press the Enter key.

6.Use the following commands to verify that all devices are varied off.

WRKCFGSTS CFGTYPE(*CTL) CFGD(*LWS) WRKCFGSTS CFGTYPE(*CTL) CFGD(*TAP) WRKCFGSTS CFGTYPE(*DEV) CFGD(*TAP) WRKCFGSTS CFGTYPE(*DEV) CFGD(*DKT) WRKCFGSTS CFGTYPE(*LIN)

WRKCFGSTS CFGTYPE(*NWI) WRKCFGSTS CFGTYPE(*NWS)

7.On the command line of the iSeries Main Menu, type the following and press the Enter key: wrkhdwprd

8.The Work with Hardware Products display appears.

Select the Change description label locations option and press the Enter key.

9.The Change Description Label Locations display appears.

Appendix A. OS/400 305

Page 319
Image 319
IBM SY44-5902-05 manual Change Description Label Locations display appears