Last battery capacity test date

This field gives the date of the last battery test in the format MM/DD/YY.

Last battery capacity test time

This field gives the time of the last battery test in the format HH:MM:SS.

Next battery capacity test date

This field gives the date of the next battery test in the format MM/DD/YY.

Next battery capacity test time

This field gives the time of the next battery test in the format HH:MM:SS.

Power sequence complete

This field indicates whether or not the power sequence is complete. Field values are Yes or No.

Fault

This field indicates whether or not a power or functional fault currently exists. Field values are Yes or No.

Note: The Display status of regulators function key (F6) on the Display Detail for Unit display is not recommended for service representative use.

Display trace log

If you select option 6 (Display trace log) on the System Power Control Network (SPCN) display, the following display appears. It shows the trace log data in both hexadecimal and EBCDIC formats. A message appears at the bottom of the display to indicate (as a hexadecimal number of bytes) the amount of data that is returned

. You can page up and down to see the entire trace log.

Note: It might take minutes to retrieve all the data; how long depends on the size of the trace log.

The Display Data display shows a section of data from the system. The leftmost

Display Data

 

 

 

 

Data

 

 

 

 

 

Offset

-------------

Hexadecimal

--------------

-----EBCDIC-----

0000

00000000

10FFD007 070010FF 04010000

0010

11020400

00001105

0100D537

00000404

N

0020

00C00000

0405000F

00000101

0703000C

0030

01030000

000C0402

0014000C

04020015

0040

00000000

000C0104

00000022

0604931F

0050

00220613

00120032

06060000

003D0603

0060

00000683

06100300

06850504

00010692

0070

06049A20

06920613

000006A2

06060000

0080

00000000

06AD0603

000006AF 061A0600

0090

06AF060A FFFF0B9D

06118521 0B9D060D

00A0

04EC0B9D 060E0597

00030204 0000000C

00B0

02060000

000C0209

0000000C

020C0000

00C0

00000000

000E0403

0014000E

04030015

00D0

00280100

D5370000

040400C0

00000405 ....

N

00E0

000F0000

01010703

000C0103

0000000C

More...

F3=Exit F12=Cancel

00000640 (hex) bytes of data returned. Retrieve trace log buffer successful.

column indicates the offset of this data line from the beginning of the data buffer that is being displayed. The next 4 columns display four, 4-byte hexadecimal numbers that begin at that offset. The last column displays the EBCDIC equivalent of these 16 bytes. Non-displayable characters (characters not part of the National

Chapter 9. System Architecture and Configuration 239

Page 253
Image 253
IBM SY44-5902-05 manual Last battery capacity test date, Last battery capacity test time, Next battery capacity test date