Table 23. Function 06 Disable CPM (continued)

Function / value

Action or description

 

 

 

06

_ _ _ D _ _

Use the Increment or Decrement buttons to display option D

 

 

(Disable).

 

 

 

06

_ _ _ _ 0 0

Press Enter to perform the Disable CPM operation. With the 00

 

 

displayed the operation was successful (the SPCN interface is

 

 

operational and the Disable message will be sent). At the next IPL,

 

 

CPM is automatically available. If FF appears instead of 00,

 

 

function 06 failed due to an SPCN communications error.

 

 

 

Function 07–Restore System Power and Perform Concurrent Maintenance Repair: Function 07 is available only on systems with SPCN and only when the system is powered on and in Manual mode. Function 07 allows you to restore power to frames that had a power failure or were powered off. It is also used for concurrent maintenance repair on bulks and fans.

When you first enter function 07, the control panel enters subfunction mode by displaying (**). Increment and decrement functions scroll to selectable values. If an SPCN communications error is present when you select a subfunction, the subfunction does not start, and FF (processing failed) displays in the rightmost display positions. Entry of a valid subfunction when no SPCN communications errors are present results in a 00 (processing successful) displayed in the rightmost display positions. Pressing Enter when ** is displayed results in exiting subfunction mode. For example:

Table 24. Function 07 Restore System Power and Perform Concurrent Maintenance Repair

Function / data

Action or description

 

 

 

07

_ _ _ _ _ _

Use the Increment or Decrement buttons to scroll to function 07.

 

 

 

07

* * _ _ _ _

Press Enter to enter function 07 subfunction mode.

 

 

 

 

 

07

0

4

_ _ _ _

Use the Increment or Decrement buttons and scroll to desired

 

 

 

 

subfunction (04 in this example). Valid subfunctions are 01, 02, 03,

 

 

 

 

04, and 05.

 

 

 

 

 

07

0

4

_ _ 0 0

Press Enter to execute subfunction 04. An SPCN communications

briefly, then

error was not present, resulting in 00. If an error occurs, FF

07

* * _ _ _ _

displays.

 

 

 

07

F 3 _ _ 0 0

Use the Increment or Decrement buttons to select a specific device

 

 

 

 

(in this case F0 - F3).

 

 

 

 

 

07

0

4

_ _ 0 0

Press Enter to exit the subfunction for the specified device and exit

briefly, then

to the subfunction level.

07

* * _ _ _ _

 

 

 

 

 

 

See the following list for valid subfunction values and their meanings.

**Cancel Request

The system returns this subfunction when you select ** for subfunction and activate enter. Use this to cancel a pending subfunction 2–5 concurrent maintenance operation. SPCN responds with an EPF 1–5 (enable panel subfunction) to clear any other subfunction range enabled previously.

01 System Power On

Chapter 5. Control Panel Functions 167

Page 181
Image 181
IBM SY44-5902-05 manual Cancel Request, System Power On, Function / data Action or description