IBM SY44-5902-05 manual Unit, Battery present

Models: SY44-5902-05

1 358
Download 358 pages 16.87 Kb
Page 252
Image 252

Display Detail for Unit

 

 

 

Frame

: 01

Load Id

: 123FE305

Unit

: 1

Reference code

: 0000

Type

: 9902

Alert status

. : 23

Model

: 001

Extended status

. : 142E

Serial number

: 10-2984631

 

AROS part number. . . . . . . . . . . . . . . : WS12948773JH

Battery present . . . . . . . . . . . . . . . : Yes

Last battery capacity test date . . . . . . . : 05/22/95 MM/DD/YY

Last battery capacity test time . . . . . . . : 10:53:02 HH:MM:SS

Next battery capacity test date . . . . . . . : 08/20/95 MM/DD/YY

Next battery capacity test time . . . . . . . : 10:53:02 HH:MM:SS

Power sequence complete . . . . . . . . . . . : Yes

Fault . . . . . . . . . . . . . . . . . . . . : No

Press Enter to continue.

F3=Exit F6=Display status of regulators F12=Cancel

The fields in this display have the following meanings:

Frame

This field shows the frame address.

Unit

This field shows the SPCN port number to which the rack-mounted unit is connected. In models 270, 7xx, 8xx, SB2, and SB3, this field shows a 1, C, or 0.

Type

This field shows the product type of the unit.

Model

This field shows the model number of the unit.

Serial number

This field shows the serial number of the unit.

Load ID

This field shows the load identifier of the unit Licensed Internal Code.

Reference code

This field shows the error code for the unit. Starting with version 4 release 5, this field will always be 0000.

Alert status

This field shows the status of the unit SPCN node.

Extended status

This field provides additional status information for the unit.

AROS part number

This field shows the alterable ROS part number.

Battery present

This field indicates whether a battery is present. Field values are Yes or No. The following four fields on battery information contain data when the field value is Yes:

238Service Functions V5R2

Page 252
Image 252
IBM SY44-5902-05 manual Unit, Battery present