Use columns 48 through 51 to enter the ending position of the Salary field. This field ends in position 60.

Column 52 specifies the decimal places of the numeric field. Use column 52 if the field contains numeric data and you would like to specify the number of decimal positions. For our example, SALARY, you will use 2 decimal positions.

Use columns 53 through 58 to title the field for reference. This example calls the field SALARY.

After you press Enter, the input specification you've just created moves to the top of the screen.

13.Display the next statement number by entering I1 in the first two positions of the line containing statement 5 and pressing Enter.

When the new statement line is displayed, press F4 to display a prompt in which to enter the input specification.

14.The field statement number 0006.00 screen appears. Here you will define the third field in the SAMPLE file. Enter the data exactly as shown in the data area prompt at the bottom of screen, as shown in Figure D-8, and then press ENTER.

Figure D-8 SEU Edit screen for line 0006.00

Columns

. . . :

1

80

 

 

Edit

QGPL/QRPGSRC

 

 

 

 

 

SEU==>

 

 

 

 

 

 

SAMPLE

 

 

 

 

 

 

FMT F

.....FFilenameIPEAF....RlenLK1AIOvKlocEDevice+......KExit++Entry+A....U1

 

*************** Beginning of data **********************************************

0001.00

FSAMPLE

IP F

128

DISK

 

0002.00

ISAMPLE

NS

 

 

 

0003.00

I

 

 

 

1

17 NAME

0004.00

I

 

 

 

18

52 TITLE

0005.00

I

 

 

 

53

602SALARY

0006.00

 

 

 

 

 

 

****************** End of data *************************************************

Prompt type .

. .

 

**

Sequence number

. . .

 

0006.00

 

Data area

 

 

 

 

 

 

 

 

 

 

 

....+...

1 ...

+...

2

...+...

3 ...

+...

4 ...

+...

5

...+...

6

I

 

 

 

 

 

 

 

61

76 CITY

 

F3=Exit

F4=Prompt

F5=Refresh

F11=Previous record

ETU400 User Guide 011603

D-13

Page 236
Image 236
Nlynx ETU400 manual Figure D-8 SEU Edit screen for line