11.Display the next statement number by typing I1 over the first two positions of the line containing statement 0004.00 and pressing Enter.
When the new statement line is displayed, press F4 to display a prompt in which to enter the input specification.
12.The field statement number 0005.00 screen appears. Here you will define the third field in the SAMPLE file. Enter the data exactly as shown in the data area prompt at the bottom of screen, as shown in Figure
Figure D-7 SEU Edit screen for line 0005.00
Columns | . . . : | 1 | 80 |
|
| Edit |
QGPL/QRPGSRC |
|
|
|
|
| |
SEU==> |
|
|
|
|
|
|
SAMPLE |
|
|
|
|
|
|
FMT F | .....FFilenameIPEAF....RlenLK1AIOvKlocEDevice+......KExit++Entry+A....U1 | |||||
| *************** Beginning of data ********************************************** | |||||
0001.00 | FSAMPLE | IP F | 128 | DISK |
| |
0002.00 | ISAMPLE | NS |
|
|
| |
0003.00 | I |
|
|
| 1 | 17 NAME |
0004.00 | I |
|
|
| 18 | 52 TITLE |
0005.00 |
|
|
|
|
|
|
****************** End of data *************************************************
Prompt type . | . . |
| ** | Sequence number | . . . |
| 0005.00 |
| |||
Data area |
|
|
|
|
|
|
|
|
|
|
|
....+... | 1 ... | +... | 2 | ...+... | 3 ... | +... | 4 ... | +... | 5 | ...+... | 6. |
I |
|
|
|
|
|
|
| 53 | 602SALARY |
|
F3=Exit | F4=Prompt | F5=Refresh |
| F11=Previous record |
F12=Cancel |
| F23=Select | prompt | F24=More keys |
Column 6 is the Form Type and must contain the letter I, which designates this record as an input specification.
Use columns 44 through 47 to enter the beginning position of the Salary field. This field starts at position 53.
ETU400 User Guide 011603 |