PCFROMPC Command
Parameter description | Parameter name | Parameter values |
Qualified file name | QFNAME | micro file name |
Transfer from which | MICLIST1 | Device name(s) of |
micro? |
| one or more |
Transfer to which micro? | MICLIST2 | micros. |
*REQUESTER device | ||
|
| name of target |
Save request definition? | SAVRQS | micro |
*YES or *NO | ||
Request name | DSPSTSMSG | Name |
Display status message? | *YES or *NO |
The PCFROMPC command transfers a file from one or more microcomputers to a single microcomputer. All micros involved in a file transfer must be of the same platform, either Mac or
NOTE: Before using PCFROMPC to transfer multiple files to a single micro, review Transferring Files With PCFROMPC and PWRTO3XB in Chapter 9 in order to minimize the risk of copying over previously transferred files.
QFNAME1 The name of the micro file to be transferred. If you are transferring a file from multiple micros, the file name, including the path name, must be identical on each micro. For additional information, see About Microcomputer Files in Chapter 3.
MICLST1 The device name of the source micro(s). To transfer a file from more than one micro, enter the device name of each. (You must be authorized to use each device you specify in the MICLIST1 parameter. If you can sign on to the device, then you are authorized to use it.)
Enter a plus sign () here and press ENTER to display multiple prompts in which to enter the device names.
Each micro from which you transfer data must be powered on, have emulation loaded, and have the AS/400
ETU400 User Guide 011603 |