PROBLEM:
“USR0032 Error detected while materializing program into AS/400 object file does not contain valid AS/400 object data”.
CAUSE:
The program you tried to transfer to the host from the PC was not previously transferred to the PC from the host.
SOLUTION:
In order to transfer a program from the micro to the host with the PGMTO3XB command, the program must have originally been transferred to the micro from the host with the PGMFROM3XB command
PROBLEM:
"USR1255 File &1 was not found on the PC disk/diskette."
CAUSE:
The "OPEN FILE" command sent to the PC emulator failed because the file name specified was not found in the current directory on the PC disk/diskette.
SOLUTION:
Use the native command mode for ETU400. Correct the error and retry the command.
PROBLEM:
"USR1256 ETU transfer failed" sometimes tied with message: "COD0006 AA Unsuccessful. Device error. Error 1331"
CAUSE:
This could be a Windows
SOLUTION:
Close the file before transferring it.
CAUSE:
The Qualified File Name could be wrong.
SOLUTION:
Make certain that the C:\ is not C:/
Make certain the extension is correct.
ETU400 User Guide 011603 |