FROM3XB Command

Parameter description

Parameter name

Parameter values

File name

FRMFILE

host file name

Library name

 

translation table member name

 

*LIBL

Member name

FRMMBR

library name

*FILE

 

 

*FIRST

 

 

*LAST

*SAVE file type?

 

*ALL

SAVTYP

*NO or *YES

Strip seq/date file

STRIP

*NO or *YES

Type of translation

TRANSLATE

*TEXT or *YES

 

 

*NO or *NONE

 

 

*DIF *BASICS

Translation file name

 

*TAB

TRNSFILE

TRANLATE

 

 

MACTAB

Library name

 

file name

 

*LIBL

Member name

TRANSMBR

library name

*ETOA1

Record length

RECL

member name

*FILE 0-9989

DDS or F&I file name

FLDDEFFILE

*NONE or *DDS

Library name

 

file name

 

*LIBL

Member name

FLDDEFMBR

library name

*FILE

Qualified file name

QFNAME1

file name

micro file name

Save request definition?

SAVRQS

*NO or *YES

Request name

DSPSTSMSG

name of request

Display status message?

*NO or *YES

The FROM3XB command transfers data from an AS/400 physical or logical file member to a file on the micro and, optionally, translates the data according to the specified translation type and translation table.

Four different types of translation can be selected: *DIF, *BASICS, *TAB, and *TEXT (see Chapter 4, Learning About ETU, for more information.). See FROM3XB Notes below.

FRMFILE The qualified file name of the AS/400 file that is to be transferred to the micro.

Library The library containing the physical file to transferred. The default, *LIBL, searches all libraries in the user's library list.

FRMMBR The FRMFILE member name. You can enter the member name or one of the following values:

*FILE Transfers the member with the same name as the FRMFILE file (the default).

*FIRST Transfers the first member arrival sequence in the file.

ETU400 User Guide 011603

10-8

Page 138
Image 138