PROBLEM:
"USR7900 System Error - INCORRECT SYSTEM SERIAL NUMBER, CALL SYSTEM SUPPORT STAFF”
or on ETU36
"USER 7900 Option (3) - error in host registration system, contact Emerald Technology"
CAUSE:
Have had ETU/36 for over a year. They are upgrading to an AS/400.
SOLUTION:
Call sales to transfer the license for $100 and get a new registration for the new machine.
CAUSE:
ETU/36 will force a registration if you go into the OWNERID screen.
SOLUTION:
Uninstall and reinstall.
The next four messages may occur when using the T03XB or PWRT03XB command to transfer a micro file to a new host file.
PROBLEM
“USR8255 For FILETYPE equal to *DATA or *SAVF, SRCSEX must be equal to *NO”.
CAUSE:
The values specified for the FILETYPE and SRCSEX parameters are not compatible with each other.
SOLUTION:
If the value for the FILETYPE parameter is *DATA or *SAVF, the value for the SRCSEQ parameter must be *NO.
PROBLEM
“USR8256 For FILETYPE equal to *SAVF, TRANSLATE must be equal to *NO”.
CAUSE:
The values specified for the FILETYPE and TRANSLATE parameters are not compatible with each other
SOLUTION:
If the value for the FILETYPE parameter is *SAVF, the value for the TRANSLATE parameter must be *NO. USR8257 For FILETYPE equal to *SAVF, RECL must be equal to O or 528.
CAUSE:
ETU400 User Guide 011603 |