Image 57

Clicking on the release catch this time will hide the waveform display controls, and revert to the previous window.

The window also offers Options, Colour mode and Window menus.

Area displayed

TQ+XR

The part of the image for which waveforms are generated is referred to as the Region of Interest. This may be selected by using the Region of Interest toolbar (see page 63). Alternatively it can be picked out (and moved around) on the Mini-Pic as described on page 63. The waveforms displayed are zoomed into the selected part of the image. To revert to displaying waveforms for the whole image, double click with the right mouse key over any portion of the Mini-Pic display.

The required part of the image can also be picked out on the Mini-Pic in exactly the same way in Full Screen mode.

Note: The Window menu includes the option to Resize to fit. This changes both the waveform display and how the waveforms are generated.

The video processing hardware can generate waveforms in one of four resolutions. At the highest resolution, a single LSB (out of 10 bits) will cause a viewable change in the waveform. This provides the best possible quality to see maximum detail. However in some applications, a lower resolution is quite sufficient. We recommend selecting the size that gives waveforms of a screen size nearest to your requirements, then stretching the window to the exact size.