You can enable additional features that are not available in standard Twinax emulations. To access these features, send text commands in the data stream. The commands must have a start and end code. Three sets (each containing a start and end code) are available:

Set 1. start code: <% stop code: >

Set 2. start code:←← stop code: $

Set 3. start code: _% stop code: _

User Defined

Usr Defined HTRN

This option is used in Twinax SPC emulation. The range is ASCII character. This option allows users to define ther own lead-in characters for the Printronix Specific commands. Select a hex value for the following codes for the User Defined option:

Start Code 1 5F

Start Code 2 5F

Stop Code 5B

Alt. Set 80-9F

Printable. Prints data in the range of hex 80 through hex 9F.

Control Code. Interprets data in the range of hex 80 through hex 9F as a control code.