Chapter 7 Diagnosing Problems

Table 15. LCD Message Troubleshooting Table

Displayed Message

Can User

Explanation

Solution

Correct?

 

 

 

 

 

 

 

 

 

 

 

HMR BANK FAN

Yes

Sensors cannot

Check that fan cable is

FLT

 

detect current in

connected. Check for

 

 

fan circuit.

obstruction of vents and

 

 

 

fan airway; remove any

 

 

 

obstructions. Check for

 

 

 

items beneath the printer

 

 

 

blocking cabinet vents.

 

 

 

Power back on the

 

 

 

printer. If this message

 

 

 

recurs, contact your

 

 

 

authorized service

 

 

 

representative.1

ILL EXT BUS ACC*

No

Fatal firmware

Contact your authorized

 

 

error on controller

service representative.1

 

 

board.

 

 

 

 

 

ILLGL OPR ACCSS*

No

Fatal firmware

Contact your authorized

 

 

error on controller

service representative.1

 

 

board.

 

 

 

 

 

INCOMPAT E-NET

Yes

Incompatible

Install a compatible NIC

 

 

network interface

to the printer then reboot.

 

 

card (NIC) is

If this message still

 

 

installed.

appears, contact your

 

 

 

authorized service

 

 

 

representative.1

INTAKE FAN FAULT

Yes

Sensors cannot

See description for HMR

 

 

detect current in

BANK FAN FLT.

 

 

fan circuit.

 

 

 

 

 

332

Page 332
Image 332