Table 15. LCD Message Troubleshooting Table | ||||
|
|
|
| |
Displayed Message | Can User | Explanation | Solution | |
Correct? | ||||
|
|
| ||
|
|
|
| |
|
|
|
| |
B49 ERROR: | No | SDRAM DIMM is | Cycle power to see if the | |
SDRAM # LOGICAL |
| not compatible with | message clears, if not, | |
BANKS* |
| the computer. | contact your authorized | |
|
| SDRAM DIMM | service representative.1 | |
|
| may not be |
| |
|
| properly installed. |
| |
|
|
|
| |
B50 ERROR: | No | SDRAM DIMM is | Cycle power to see if the | |
SDRAM LOGIC |
| not compatible with | message clears, if not, | |
COMB BANKS* |
| the computer. | contact your authorized | |
|
| SDRAM DIMM | service representative.1 | |
|
| may not be |
| |
|
| properly installed. |
| |
|
|
|
| |
B50 STATUS: XX% | No | Emulation software | No action is required. | |
CLEAR FLASH |
| sucessfully loaded |
| |
|
| in RAM. Old |
| |
|
| program being |
| |
|
| deleted from flash |
| |
|
| memory. |
| |
|
|
|
| |
B51: ERROR SDA | No | Problem with I2C | Contact your authorized | |
LINE STUCK LOW |
| bus. Either | service representative.1 | |
|
| SDRAM or PCI |
| |
|
| card shorting out |
| |
|
| the bus. |
| |
|
|
|
| |
B51 STATUS: XX% | No | Status message | No action is required. | |
PROGRAMMING... |
| file sucessfully |
| |
|
| loaded and is |
| |
|
| being saved in |
| |
|
| flash memory. |
| |
|
|
|
| |
B55 STATUS: SEND | No | EC program | No action is required. | |
PROGRAM TO EC |
| downloaded and |
| |
|
| being programed |
| |
|
| in EC. |
| |
|
|
|
|