| Fault Messages | |
Table 15. LCD Message Troubleshooting Table | ||||
|
|
|
| |
Displayed Message | Can User | Explanation | Solution | |
Correct? | ||||
|
|
| ||
|
|
|
| |
|
|
|
| |
ERROR: WRITING | No | Hardware or | Contact your authorized | |
TO FLASH |
| software fault in | service representative.1 | |
|
| flash memory. |
| |
|
|
|
| |
ERROR: WRONG | No | The printer | Contact your authorized | |
CHECKSUM |
| received the | service representative.1 | |
|
| complete program |
| |
|
| but the checksum |
| |
|
| did not match. |
| |
|
|
|
| |
ERROR: WRONG | No | The SPX inserted | Contact your authorized | |
OEM OR PRINTER |
| in the debug port is | service representative.1 | |
TYPE |
| not intended for |
| |
|
| this model printer |
| |
|
| or this OEM. |
| |
|
|
|
| |
ETHERNET | N/A | Status message | No action is required. | |
ADAPTER BEING |
| indicating that the |
| |
INITIALIZED |
| Network Interface |
| |
|
| Card is processing |
| |
|
| the boot |
| |
|
| procedure. |
| |
|
|
|
| |
ETHERNET | N/A | Status message | No action is required. | |
DETECTED |
| indicating that the |
| |
|
| Network Interface |
| |
|
| Card has |
| |
|
| established |
| |
|
| connection. |
| |
|
|
|
| |
EXCESS RBN | Yes | Displayed when | Install a new ribbon. | |
WEAR |
| ribbon reaches end |
| |
Install New RBN |
| of life |
| |
|
|
|
|
329