Chapter 4 LinePrinter Plus Emulation (with PCL-II)

Auto LF

This option defines the printer actions when print data is received past the forms width setting.

Enable (default). Performs an automatic carriage return and line feed when data is received past the forms width.

Disable. Discards any data past the forms width.

Define LF Code

The Define LF Code option controls the action of the printer when it receives a Line Feed code (hex 0A) from the host computer. If this feature is enabled, each time the printer receives a Line Feed, it inserts an additional Carriage Return code (hex 0D) into the data stream. This feature is required if the host computer does not send carriage returns to the printer.

LF = LF (default). Does not add a carriage return with a line feed.

LF = CR + LF. Adds an extra carriage return with each line feed.

Printer Select

Disable (default). Ignores the ASCII DC1 and DC3 control codes.

Enable. Disables the printer when a DC1 control code is received, and enables the printer when a DC3 control code is received.

242

Page 242
Image 242
Printronix P7000 user manual 242