Chapter 4 Coax/Twinax (CTHI) Emulation
Format Control
Enables the printer to reflect the same spacing as CTPC model printers after absolute and relative move commands are executed.
•Disable (default). Reflects distance, generated by the IGP/VGL feature, IGP/PGL feature, and Hex Transparent control code sequence, in the new position (after absolute and relative move commands are executed).
•Enable. Does not reflect distance, generated by the IGP/VGL feature, IGP/PGL feature, and Hex Transparent control code sequence, in the new position (after absolute and relative move commands are executed).
Max. Print Width
Set the maximum print width at either 13.2 inches or the maximum width of the printer. The default is 13.2 inches.
Buffer Print
•Disable (default). The printer will print normally.
•Enable. The printer prints the EBCDIC data and control codes received from the host as hex values. Refer to page 315 for information on how to obtain a hex code printout.
NOTE: Use of this parameter may alter print attributes set by the host computer. A power cycle may be required after changing Buffer Print from enable to disable.