Chapter 4 ADVANCED USER

In a non-CT system, changing characters sets in LP+ causes the active IGP to change to the same character set if the selected set exists in IGP. If the active IGP has no access to the selected set, no changes are made. Selecting a new character set in the active IGP causes the LP+ to change to the same character set if the selected character set exists in the active LP+ protocol. Not all sets are shared between emulations in the Standard group of character sets. As a result, selecting a set in the Standard group of LP+ or IGP emulation may or may not cause the other emulation to have the same set.

NOTE: The front panel option, Set Sharing, has no effect on the LP+ and CT/LP+ builds. The option only applies to the builds with IGP.

This option is not available in the PCL-II or LG emulation.

Shuttle Timeout

The amount of time the shuttle continues moving after no data is received. If your host is slow, setting the number to a higher value will prevent the printer from spending time shuttling up and down between data bursts.

Slow Paper Slew

Disable (default). The paper will slew and stack paper at maximum speed.

Enable. Causes the paper to stack at a slower rate. This ensures that certain forms will stack neatly.

Alarm

On (default). An audible alarm sounds (3 beeps) when a fault occurs, such as a paper jam.

Cont. Beep. A continuous audible alarm sounds when a fault occurs, which can be stopped by pressing CLEAR.

Off. No audible alarm will sound.

286

Page 286
Image 286
Printronix P7000 user manual Shuttle Timeout, Slow Paper Slew, Alarm