| Fault Messages | |
Table 15. LCD Message Troubleshooting Table | ||||
|
|
|
| |
Displayed Message | Can User | Explanation | Solution | |
Correct? | ||||
|
|
| ||
|
|
|
| |
|
|
|
| |
B23 ERROR: | No | FLASH SIMM may | Cycle power to see if the | |
DECOMPRESS |
| not be properly | message clears, if not, | |
CKSUM* |
| installed. | contact your authorized | |
|
|
| service representative.1 | |
| N/A | Status message | No action is required. | |
INITIALIZING |
| informing the |
| |
|
| operator that |
| |
|
| software is being |
| |
|
| downloaded |
| |
|
| through one of the |
| |
|
| printer’s I/O ports |
| |
|
| using the |
| |
|
| download |
| |
|
| activation. |
| |
|
|
|
| |
| N/A | Waiting for EC/DC | No action is required. | |
WAITING FOR EC |
| Powerup |
| |
STATUS |
| handshake. |
| |
|
|
|
| |
B40 ERROR: | No | SDRAM DIMM | Cycle power to see if the | |
SDRAM EEPROM |
| may not be | message clears, if not, | |
CKSUM BAD* |
| properly installed. | contact your authorized | |
|
|
| service representative.1 | |
B41 ERROR: DIM | No | SDRAM DIMM is | Cycle power to see if the | |
MEMORY NOT |
| not compatible with | message clears, if not, | |
SDRAM* |
| the computer. | contact your authorized | |
|
| SDRAM DIMM | service representative.1 | |
|
| may not be |
| |
|
| properly installed. |
| |
|
|
|
| |
B42 ERROR: | No | SDRAM DIMM is | Cycle power to see if the | |
SDRAM ROWS NOT |
| not compatible with | message clears, if not, | |
ALLOWED* |
| the computer. | contact your authorized | |
|
| SDRAM DIMM | service representative.1 | |
|
| may not be |
| |
|
| properly installed. |
| |
|
|
|
|
321