3 – Managing Fabrics Zoning a Fabric

S

3.7.1.4

Zoning Database

Each switch has its own zoning database. The zoning database is made up of all aliases, zones, and zone sets that have been created on the switch or received from other switches. The switch maintains two copies of the inactive zoning database: one copy is maintained in temporary memory for editing purposes; the second copy is maintained in permanent memory. Zoning database edits are made on an individual switch basis and are not propagated to other switches in the fabric when saved.

There are two configuration parameters that affect the zoning database: Interop Auto Save and Default Visibility. The Interop Auto Save parameter determines whether changes to the active zone set that a switch receives from another switch in the fabric will be saved to permanent memory on that switch. The Default Visibility parameter permits or prohibits communication among ports/devices when there is no active zone set. Refer to ”Configuring the Zoning Database” on page 3-47for information about zoning configuration.

3.7.1.4.1

Viewing Zoning Limits and Properties

Zoning limits vary depending on the firmware installed on the switch. To view zoning limits and properties on a switch, do the following:

1.In the faceplate display, open the Zoning menu and select Edit Zoning to open the Edit Zoning dialog.

2.Choose one of the following:

„In the zone sets tree (left windowpane), right-click on the top zonesets entry, a zone set, a zone, or a zone member. In the popup menu, select Properties.

„In the zone set tree (left windowpane), select the top zonesets entry, a zone set, a zone, or a zone member. Open the Edit menu and select Properties.

3.View the zoning limits and properties information in the Properties dialog.

4.Click the OK button to close the Properties dialog.

The zoning limits for switches with 5.02 firmware are:

„MaxZoneSets is 256. The maximum number of zone sets that can be configured on the switch. This will be enforced during the configuration of zoning and during a zoning database merge from the fabric.

„MaxZones is 2000. The maximum number of zones that can be configured on the switch. This will be enforced during the configuration of zoning and during a zoning database merge from the fabric.

3-42

59097-02 B

Page 88
Image 88
Q-Logic 5600 manual Zoning Database, Viewing Zoning Limits and Properties