A – Command Line Interface Set Config Command

S

The following is an example of the Set Config Threshold command:

SANbox

xxxx

#> admin

start

 

 

SANbox

xxxx

(admin)

#> config edit

 

 

SANbox

xxxx

(admin-config) #> set config

threshold

 

A list

of attributes

with formatting and

current values will follow.

Enter a new

value or

simply press the ENTER key to

accept the current value.

If you wish to terminate this process before reaching the end of the list

press 'q' or 'Q' and the ENTER

key to do so.

 

 

ThresholdMonitoringEnabled

(True / False)

[False

]

CRCErrorsMonitoringEnabled

(True / False)

[True

]

RisingTrigger

(decimal value, 1-1000)

[25

]

FallingTrigger

(decimal value, 0-1000)

[1

]

SampleWindow

(decimal value, 1-1000 sec)

[10

]

DecodeErrorsMonitoringEnabled

(True / False)

[True

]

RisingTrigger

(decimal value, 1-1000)

[200

]

FallingTrigger

(decimal value, 0-1000)

[0

]

SampleWindow

(decimal value, 1-1000 sec)

[10

]

ISLMonitoringEnabled

(True / False)

[True

]

RisingTrigger

(decimal value, 1-1000)

[2

]

FallingTrigger

(decimal value, 0-1000)

[0

]

SampleWindow

(decimal value, 1-1000 sec)

[10

]

LoginMonitoringEnabled

(True / False)

[True

]

RisingTrigger

(decimal value, 1-1000)

[5

]

FallingTrigger

(decimal value, 0-1000)

[1

]

SampleWindow

(decimal value, 1-1000 sec)

[10

]

LogoutMonitoringEnabled

(True / False)

[True

]

RisingTrigger

(decimal value, 1-1000)

[5

]

FallingTrigger

(decimal value, 0-1000)

[1

]

SampleWindow

(decimal value, 1-1000 sec)

[10

]

LOSMonitoringEnabled

(True / False)

[True

]

RisingTrigger

(decimal value, 1-1000)

[100

]

FallingTrigger

(decimal value, 0-1000)

[5

]

SampleWindow

(decimal value, 1-1000 sec)

[10

]

Finished configuring attributes.

 

 

This configuration must be saved (see config save command) and

 

activated (see config activate

command) before it can take effect.

 

To discard this configuration use the config cancel command.