A

A – Command Line Interface Set Config Command

threshold

Initiates a configuration session by which to generate and log alarms for selected events. The system displays each event, its triggers, and sampling window one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets. These parameters must be saved in a configuration and activated before they will take effect. Refer to the ”Config Command” on page A-17for information about saving and activating a configuration. Table A-21describes the Set Config Threshold parameters. The switch will down a port if an alarm condition is not cleared within three consecutive sampling windows (by default 30 seconds). Reset the port to bring it back online. An alarm is cleared when the threshold monitoring detects that the error rate has fallen below the falling trigger.

Table A-21. Set Config Threshold Parameters

Parameter

 

Description

 

 

Threshold Monitoring Enabled

Master enable/disable parameter for all events.

 

Enables (True) or disables (False) the generation

 

of all enabled event alarms. The default is False.

CRCErrorsMonitoringEnabled

The event type enable/disable parameter.

DecodeErrorsMonitoringEnabled

Enables (True) or disables (False) the generation

of alarms for each of the following events:

ISLMonitoringEnabled

„

CRC errors

LoginMonitoringEnabled

„

Decode errors

LogoutMonitoringEnabled

„

ISL connection count

LOSMonitoringEnabled

„

Device login errors

 

 

„

Device logout errors

 

„ Loss-of-signal errors

Rising Trigger

The event count above which a rising trigger

 

alarm is logged. The switch will not generate

 

another rising trigger alarm for that event until

 

the count descends below the falling trigger and

 

again exceeds the rising trigger.

Falling Trigger

The event count below which a falling trigger

 

alarm is logged. The switch will not generate

 

another falling trigger alarm for that event until

 

the count exceeds the rising trigger and

 

descends again below the falling trigger.

Sample Window

The period of time in seconds in which to count

 

events.

 

 

 

59097-02 B

A-69

Page 249
Image 249
Q-Logic 5600 manual Table A-21. Set Config Threshold Parameters