Sampling
M-86
MV-8800 Owner’s Manual
4.
Press [F5](Stop).
Stops sampling. The RESULT popup (Screen Guide; p. 211) will appear.
Audition the sampled result. Each sampled data item will be assigned to a sample number.
5.
Set the parameters for adjusting.
Start Point / End Point
Specify the points at which the sample will start playing and stop playing. The Start Point - End Point region
is highlighted.
Range: 000000000.000–The end of sample
BPM Base Note
Draws measure and beat lines on the displayed sample.
Range: , , (initial value), , / x 0–x 4–x 65535
Original Key
Specifies the basic pitch. When you play this key, the sample will sound at its original pitch (the pitch at which
it was sampled).
Range: 0 (C -)–60 (C 4)–127 (G 9)
Truncate
Deletes the portions of the sample before the Start Point and after the End Point.
Range: Off, On (
)
Normalize
Raises the overall level of the sample without allowing the maximum level to be exceeded.
Range: Off, On (
)
Loop
Specifies how [F4](Preview) will operate. You can also make setting of loop playback when you assign the
sample to pad as a Partial or an Audio Phrase.
The BPM is displayed below the BPM Base Note. The displayed BPM value is calculated from the BPM Base
Note setting and the playback length of the sample.
You can’t use Undo function to bring back a truncated or normalized sample.
Value Explanation
Off The sample will audition once from the Start Point to the End Point.
On The sample will repeatedly audition from the Start Point to the End Point.
MV-8800_e.book 86ページ 2006年11月10日 金曜日 午後1時48分