Toshiba DK40I, dk14 Program 76-1X-Y– DK14, DK40i, all RCTUs and BCUs, Program 76-1Overview, 3-162

Models: DK40I dk14

1 424
Download 424 pages 49.24 Kb
Page 206
Image 206
Program 76-1(X-Y) – DK14, DK40i, all RCTUs and BCUs

System & Station

Program 76-1(X-Y) – DK14, DK40i, all RCTUs and BCUs

Program 76-1(X-Y) – DK14, DK40i, all RCTUs and BCUs

Processor Type: DK14, DK40i, all RCTUs and BCUs

Program Type: System

Initialized Default: Port 1 (Type 1), Ports 2~4 (Type 0)

￿ ￿￿ ￿ ￿￿

￿￿ ￿ 6SNU ￿ ￿ +ROG ￿ 6SNU ￿ Program 76-1 Overview3-162

SELECT = 1

X = Port Number (1~4)

Y=Port Type (0~6), see table below.

Manual backgroundManual background +ROG ￿ 6SNU ￿ ￿ +ROG ￿ 6SNU ￿ ￿ +ROG

Run Program 91-2

System power must be cycled or Program 91-2 must be run to transfer Program 76-1 data entries from temporary memory to working memory.

Port Number

1

2

3

4

Port Type (0~6)

Program 76-1 Overview

This program assigns each installed WSIU (DK14 only), TSIU (DK40i only) or RSIU/RSIS (DK424 only) port to a function.

For Program 76-1(X-Y):

X identifies the WSIU, TSIU port number 1~2 or RSIU/RSIS/RMDS port number 1~4. Y identifies the WSIU, TSIU or RSIU/RSIS/RMDS port function as shown below:

Port Type (Y)

Function

0

No port equipped. This should be used for any of the four RSIU/RSIS/RMDS ports that are not used.

 

 

1

TTY or modem1.

TTY RS-232 port (set Program 77-1, LED 14 Off; DK14, DK40i, DK424 or DK424i).

 

RMDS modem port (set Program 77-1, LED 14 On; DK424 or DK424i).

 

 

2

SMDR

 

 

3

MIS or SMIS (DK424)

 

 

4

SMDI

 

 

5

Open Architecture Interface (see Program 77-4) (DK424 R3.2)

 

 

6

Caller ID output to Caller ID interface box (DK14 only)2

1.If port type code 1 is set, then Program 77-1, LED 14 status determines if the port operates as a system administration/ maintenance modem (LED 14 On) or an RS-232 administration/maintenance TTY port (LED 14 Off). For modem operation, an RMDS piggy-back PCB is required, for RS-232 TTY port, a TSIU, WSIU, RSIU/RSIS/RMDS PCB may be used.

2.If the DK14 CO lines must pass Caller ID information to the Toshiba telephones, LCD/RPCI-DI, an interface box, TC1041 (MLX-41), must be connected to one of the WSIU outputs. For more information, see the Caller ID instructions in Chapter 1 – DK14 Installation of the Strata DK I&M Manual.

Port types set in this program override RSSU, PIOU, and/or PIOUS function codes (41, 42, 43) set in Program 03. To activate changes made to this program, system power must be turned off/on or Program 91-2 must be run.

Communication Parameters: SMDI, MIS or SMIS, TTY, IMDU/RMDS, Caller ID, OAI: 7

bits, even parity, 1 stop bit. SMDR: 8 bits, no parity, 1 stop bit.