Program 14-71 – Queue Size for Alarm, Immediate

Automatic Call Distribution

Program 14-71 – Queue Size for Alarm, Immediate Assignments

Program 14-71 – Queue Size for Alarm, Immediate

Assignments

Initialized Default: Queue Size = 010

￿ ￿￿ ￿ ￿￿￿￿ ￿ 6SNU ￿ ￿ +ROG ￿ 6SNU ￿ ￿ Program 14-71 Overview6-29

SELECT = 71

SELECT = ACD Group Number

Manual backgroundManual background +ROG ￿ 6SNU ￿ ￿ +ROG ￿ 6SNU ￿ ￿ +ROG

DATA = Queue Size

Automatic Call Distribution

Processor

ACD Group Numbers

Queue Size

DK40i

01~08

001~012

 

 

 

RCTUA

01~08

001~016

 

 

 

RCTUBA/BB, B1CU

01~08

001~048

 

 

 

RCTUC/D, B2CAU/BU, B3CAU/BU

01~16

001~144

 

 

 

RCTUE/F, B5CAU/BU

01~16

001~200

 

 

 

ACD Group Number

Queue Size

Program 14-71 Overview

The system causes the Supervisor 5HVHW￿4XHXH￿$ODUP button to flash and the Supervisor telephone sounds immediately a one second On, one-half Off beeping alarm when the number of calls in the ACD queue exceeds the number set in this program. Program 14-8 DATA must be set to “1” if using this option (see Program 14-8 for more information).